References
240 Heron™ HD3130
RGB Auto Delay Time
Specifies the delay time for running the RGB auto mode after the scanner has 
gone into an idle state (no label reading, label programming or communication 
with Host). 
The delay can be set within a range of zero (0) to 255 milliseconds (5 seconds) 
i
n
 500ms increments. The value 0x00 means Auto Mode is disabled. 
To set the time:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 500 (setting is in 500ms increments). Pad the 
re
sult with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Go to 
page 79
 and scan the bar code: SELECT RGB AUTO DELAY TIME.
5. Scan the appropriate two digits from the keypad in 
Appendix D, Keypad
, that 
represent the duration which was determined in the steps above. 
NOTE
If you make a mistake before the last character, scan the CANCEL bar code 
to abor
t and not save the entry string. You can then start again at the 
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to 
set this feature.
Table 17. RGB Auto Delay Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1,000ms (1 sec.)
10,000ms (10 
sec.)
60,000ms (60 secs.)
2 Divide by 500 
01 02 20 120
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT RGB AUTO DELAY TIME
5
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘1’ ‘0’ and ‘2’ ‘2’ and ‘0’ ‘1’,  ‘2’ and ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE