New Features | 3
New Features
SFTOS 2.5.3 adds improved SFTOS internals, but no changed CLI.
SFTOS 2.5.2 adds:
A substantial Technical Support interface that is not accessible through the standard CLI modes
and is not publicly documented
Support for new S-Series platforms, including the S50N, S50N-DC, S25P, and S25P-DC
Other Changes to the Document
This edition contains only minor edits, with no changes to syntax.
Changes in the previous edition include:
Unsupported Features: The major change was to note features that were at least partially
implemented in SFTOS 2.5.2, but not supported by Dell Force10, because they were not sufficiently
tested. The Release Notes document for SFTOS 2.5.2.2 contains a list of those features, including
DSCP options in QoS commands, DVMRP, GARP, GVRP, IP subnet-based VLANs, MAC-based
VLANs, PIM-DM, protocol-based VLANs, VLAN-Stacking, and the Web UI.
The SFTOS Web User Interface (Web UI) chapter is removed from this book, and the Command
History fields of commands supporting those unsupported features are updated in this edition with the
following statement:
Version 2.5.2 Unsupported: not tested in 2.5.2
The ACL chapter now states that both MAC and IP ACLs can be applied to the same interface. See
Chapter 21, “ACL Commands,” on page 379.
The adu.iOdutagCEs commands (global and interface) are added to the DHCP Server Commands
chapter. See DHCP Server Commands on page 231.
Corrections to existing commands include a:,duEo rgE (see igmp enable (interface) on page 274)
and Og nnetnEsbaOEuCsWnC (see classofservice trust on page 329).
Changes to the previous edition of this guide for SFTOS 2.5.2 include:
The previously separate VLAN section in the System Configuration chapter, and the GARP
(including GMRP and GVRP) and VLAN-Stacking chapters are combined into a separate VLAN
chapter.
The show classofservice ip-dscp-mapping on page 332 command from an earlier release is added
to the book.
Command options from an earlier release for show diffserv service on page 360 added to the book
Descriptions of monitor session on page 95 and show monitor session on page 101 modified
Updated features list in SFTOS Features on page 13.
SNTP chapter: More details added
Multicast SNTP servers is removed as an SNTP option. See Time Commands on
page 243.

Table of Contents

Other manuals for Dell Force10 S2410-01-10GE-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Force10 S2410-01-10GE-24P and is the answer not in the manual?

Dell Force10 S2410-01-10GE-24P Specifications

General IconGeneral
ManageableYes
Jumbo Frame SupportYes
Product TypeSwitch
Uplink Ports4 x 10 Gigabit SFP+
MAC Address Table Size32K entries
Operating Temperature0 °C to 40 °C
Storage Temperature-40 °C to 70 °C
Power SupplyInternal