448 | OSPF Commands
www.dell.com | support.dell.com
show ip ospf virtual-link brief
This command displays the OSPF Virtual Interface information for all areas in the system.
Syntax
show ip ospf virtual-link brief
Mode
Privileged Exec and User Exec
Report Fields
Area Id—Is the area ID of the requested OSPF area.
Neighbor—Is the neighbor interface of the OSPF virtual interface.
Hello Interval—Is the configured hello interval for the OSPF virtual interface.
Dead Interval—Is the configured dead interval for the OSPF virtual interface.
Retransmit Interval—Is the configured retransmit interval for the OSPF virtual interface.
Transit Delay—Is the configured transit delay for the OSPF virtual interface.
trapflags
This command enables and disables OSPF traps.
Syntax
[no] trapflags
The no trapflags command disables OSPF traps.
Default
enabled
Mode
Router OSPF Config
Usage
Information
Use this command in conjunction with other SNMP management commands, described in SNMP
Management Commands on page 77.

Table of Contents

Other manuals for Dell Force10 S2410-01-10GE-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Force10 S2410-01-10GE-24P and is the answer not in the manual?

Dell Force10 S2410-01-10GE-24P Specifications

General IconGeneral
ManageableYes
Jumbo Frame SupportYes
Product TypeSwitch
Uplink Ports4 x 10 Gigabit SFP+
MAC Address Table Size32K entries
Operating Temperature0 °C to 40 °C
Storage Temperature-40 °C to 70 °C
Power SupplyInternal

Related product manuals