EasyManuals Logo

Delta VFD-E Series User Manual

Delta VFD-E Series
435 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #322 background imageLoading...
Page #322 background image
C-2
C.1 Capacity Formulas
1. When one AC motor drive operates one motor
The starting capacity should be less than 1.5x rated capacity of AC motor drive
The starting capacity=
)(_____5.1
375cos973
2
kVAdrivemotorACofcapacitythe
t
NGD
T
Nk
A
L
2. When one AC motor drive operates more than one motor
2.1 The starting capacity should be less than the rated capacity of AC motor drive
Acceleration time
60 seconds
The starting capacity=
)(_____5.11
cos
111 kVAdrivemotorACofcapacitythek
n
n
Pknn
Nk
sCss
T
s
T
Acceleration time
60 seconds
The starting capacity=
)(_____1
cos
111 kVAdrivemotorACofcapacitythek
n
n
Pknn
Nk
sCss
T
s
T
2.2 The current should be less than the rated current of AC motor drive(A)
Acceleration time
60 seconds
)(______5.111 AdrivemotorACofcurrentratedthek
n
n
In SM
T
S
T
Acceleration time
60 seconds
)(______11 AdrivemotorACofcurrentratedthek
n
n
In SM
T
S
T

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-E Series and is the answer not in the manual?

Delta VFD-E Series Specifications

General IconGeneral
BrandDelta
ModelVFD-E Series
CategoryMedia Converter
LanguageEnglish

Related product manuals