EasyManuals Logo

DigiDesign D-Show Profile User Manual

DigiDesign D-Show Profile
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #191 background imageLoading...
Page #191 background image
Chapter 21: Snapshots 181
Using Scope Sets
The configuration of the Recall Safe page can be stored as a
Scope Set settings file. Scope Sets can be previewed, recalled
and transferred just like D-Show plug-in, EQ and Dynamics
settings.
To store the current Recall Safe settings as a Scope Set:
1 Configure the Recall Safe page as desired.
2 Click the Scope Sets icon (the folder icon located above and
to the right of the parameter matrix).
3 Click New.
To preview and recall a saved Scope Set:
1 From the Recall Safe page, click the Scope Set icon to display
the Scope Set window.
2 If necessary, choose the appropriate Scope Sets folder by
clicking and selecting it from the Folder selector.
3 Do any of the following:
To preview an existing Scope Set, click its name in the
Scope Sets window.
To load the currently selected Scope Set, press Enter or
click the Close box (X) in the Scope Sets window title bar.
To cancel without changing Recall Safe settings, click
Cancel.
Automation Safing Channels
You can suspend the effect of snapshots on individual chan-
nels using any of the following Automation Safe controls:
Input Channel Safes Temporarily suspend the effect of snap-
shots on individual Input Channels and FX Returns from the
control surface. Function of the Selected Channel Safe switch
is determined by the current setting in the Options > Interac-
tion page for Input Safe Switches.
On-Screen Safe Buttons Each on-screen channel has a safe but-
ton that controls its Channel Safe status.
To toggle the Safe status of an Input Channel or FX Return
directly from the channel strip:
1 Go to the Options page and click the Interaction tab.
2 Under Input Safe Switches, select the “Act as Automation
Safes” option.
3 Press the Safe switch in the Input section, or click the
on-screen Safe button) for each of the Input Channels or FX
Returns you want to safe. The Safe switch lights solid to indi-
cate that the channel is automation safed.
Scope Sets window
See Chapter 20, “Shows and File Management” for instruc-
tions on creating custom folders and transferring D-Show
data.
Scope Sets
Folder selector
On-screen Automation Safe button
You can also control channel automation safe status in the
Recall Safe tab. See “Channel Safe” on page 180.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DigiDesign D-Show Profile and is the answer not in the manual?

DigiDesign D-Show Profile Specifications

General IconGeneral
BrandDigiDesign
ModelD-Show Profile
CategoryMusic Mixer
LanguageEnglish

Related product manuals