OSD Setup Manual
44
Alert Configuration Set
<Alert Configuration Set> provides 3 combinations of Alert Notification, IP, and
Port.
Alert Notification
4 options are included in this item; <OFF>, <Event>, <Alive>, and <Both>.
<OFF>: The Alert Notification is turned off.
<Event>: When the alarm is triggered, the DVR will send an alert message to the
CMS.
<Alive>: The DVR will send an alive message to the CMS every N second just to
show users that the connection between the DVR and CMS is in effect.
The time interval N can be adjusted in <Alive Interval>.
<Both>: This enables the DVR to send both Event and Alive alert messages to
the CMS.
Alert IP
The Alert IP must match the IP address of the computer.
Alert Port
The ports for DVR and the CMS Alert MUST be the same.
Alive Interval
Users can define the time interval (1 to 255 seconds) between each alive message.
This item will not be accessible if the alert notification menu is set to <OFF> or
<Event>.
< Event Full Screen >
This function allows the DVR to display the alarm channel in full screen size when an alarm
is triggered.
Select <None> to disable this function, <Main> to display the alarm channel on Main
Monitor when an alarm is triggered, <Call> to display the alarm channel on Call Monitor, or
select <Both> to display the alarm channel on both Main Monitor and Call Monitor.
< Event Duration >
This item determines the duration of the buzzer and Alarm Out relay function after an alarm
is triggered. The available event duration range is from 5 second to 999 seconds.