Data preparation
6.15
Training manual • Basic training • Status 03.14
EOS P 396
6
Support parts (dummy parts) can be positioned under parts critical for distortion
to improve the evenness.
- The distance between the dummy parts and the real part should be
approx. 0.6 mm to 1 mm.
- The number and distance to the dummy parts depend on the volume and
geometry of the real part.
- The dummy parts must be separate from each other to avoid transferring
distortion.
Parts critical for distortion with long surfaces should as far as possible be
positioned diagonally in the building chamber.
1 Part 2 Dummy part