Adjustment
EPSON Stylus Color 3000 Service Manual
4-20
7. Adjust the paper tray extension to the rear edge of the paper. Then press Enter, and the Sensor Check
menu appears on the monitor.
8. Remove the paper or tool.
9. To exit the adjustment program, return to the main menu, select END and press Enter.
PG Adjustment
1. Enter the Sensor Check menu (See page).
2. Select PG and press Enter.
3. Set the PG adjust lever to the front (+) and press Enter.
4. Set the PG adjust lever to the rear (-) and press Enter; the Sensor Check menu appears.
5. Select Return and press Enter; the main menu appears.
6. Select END to exit the program.