ECI Multi Functional Weighing Controller Operating Manual
Page 297
Warning
102
Tare active!
No zeroing can be made while the tare is active.
Warning
103
Negative Load
No taring can be possible for the negative loads.
Warning
104
No taring possible
No taring can be possible for the zero value.
Warning 108
RestoreFact.Setting
s
Factory Settings will be restored.
Warning
109
Restarting
The device will be restarted.
Warning 110 Output will change
Filling or discharging valves can be opened by activating the units connected
to the relay outputs.
Warning 120 FillingTimeLapse
It shows that no weight change occurs during the "FillingTimeLapse" period
while filling.
Warning 121 SiloValue Max
It is shown when the maximum batching value of 100.000 for silo is
exceeded.
Warning
122
SiloValue Min
It is shown when the maximum batching value of 0 for silo is calculated.
Warning
123
InsufficientCapacity
Batching value is more than the capacity.
Warning
124
Total < Package
Total value of the batching cannot be less than the package value.
Warning 125 Recipe Empty!
The filling operation is unable to be started as the weight values for the silo
related to the recipe intended to be batched is entered as zero.
Error 126 ToleranceError!
Errors more than detected occurred at any of the silos as the result of
batching.
Error 127
Discharge.TimeLap
se
It shows that no weight change occurs during the "FillingTimeLapse" period
while discharging.