Pop-Up
Power Blazer 987
Modify DS0/E0
Payload Content allows the selection of the payload content that will
be applied to all TX timeslots when tapping the Set All button: Pattern,
Idle, or Tone.
Set All applies the selected payload content to all TX timeslots.
TX
Pattern/Idle/Tone button: Tap once or several times on each
timeslot until the desired payload content appears: Pattern
(default), Idle, or Tone. For E0, timeslots 0 and 16 (PCM30 and
PCM30 CRC4) are not configurable; timeslot 0 generates the
FAS/NFAS framing; timeslot 16 generates a static MFAS frame when
TX Signaling is disabled and generates a frame with Signaling
capability when TX Signaling is enabled.
Pattern: The pattern used is the one selected from Pattern on
page 223.
Tone (Hz) allows the selection of a tone for digital milliwatt testing.
The signal output power, when converted to analog, is 0 dBm.
Choices are 1000 Hz and 1004 Hz (default). The selected tone
applies to all timeslots set to Tone.
Idle uses the Idle code byte from the Idle field: 00 to FF (default
is 7F). The selected Idle code applies to all timeslots set to Idle.
Binary check box allows either displaying the Idle code value in
binary (when selected) or in hexadecimal (default).
Note: The timeslots set to Idle or Tone can be changed from Idle to Tone and vice
versa even when the test is running; their values can also be changed.