1588 PTP (Client)
Pass/Fail Verdict
Pass/Fail Verdict check box when selected (default) enables the use of the
pass/fail verdict. The global pass/fail verdict is based on the following
criteria: alarms (Link Down, Loss Sync, Loss Announce, Unusable
(G.8265.1), and/or QL Mismatch (when QL Mismatch Monitoring is
enabled)), or the test is automatically aborted (service request denied,
session canceled, or no reply for G.8265.1; sync message rate changed for
G.8275.1). Only available with 1588 PTP test.
Restore 1588 PTP Defaults
Reverts the test application to its default factory settings. Only available
with 1588 PTP test.
G.8275.1
G.8275.2
QL-PRC/PRS (default) 6, 7,
135, 140
Primary Reference Clock Traceable (G.811)
QL-SSU-A/ST2 150 Type I or V slave clock (G.812)
Traceable to Stratum 2 (G.812 Type II)
QL-SSU-B/ST3E 160 Type VI slave clock (G.812)
Traceable to Stratum 3E (G.812 Type III)
QL-SEC/EEC1/ST3/EEC2 165,
248, 255
Synchronous equipment clock (G.813 Option I)
Ethernet equipment clock (G.8262 Option I)
Traceable to Stratum 3 (G.812 Type IV or G.8262 Option II)
Ethernet equipment clock (G.8262 Option II)
Profile
ITU
Quality Level
value
PTP
Clock
Class
Description