Test Control
Power Blazer 767
Discover Remote
Remote Modules Discovery (3rd Party Loopback)
Use Stream Destination from Test Application check box when
selected (default), it uses the stream destination configuration
parameters from the test application to communicate with the
third-party loopback unit. Only available with single-stream test
applications.
Loop Layer allows selecting the layer of loop messages: L2: Ethernet,
L3: IP, or L4: UDP/TCP.
Destination MAC Address (L2) allows specifying the stream
destination MAC address. Not configurable when the Use Stream
Destination from Test Application check box is selected.
Destination IP Address (L3/L4), allows specifying the stream
destination IP address. Not configurable when the Use Stream
Destination from Test Application check box is selected.
Quick Ping tests if the destination IP address can be reached. A
message displays if the ping attempt is Successful or Failed.
Destination Port (L4) allows selecting the stream destination UDP
port. Not configurable when the Use Stream Destination from Test
Application check box is selected.
Remote Module ID indicates the unit ID of the remote unit.
Remote Status indicates the status of the remote unit.