CHAPTER 5
PAGE 26
PAGE DATE: 24. February 2017
MAINTENANCE MANUAL EXTRA 300LT
Instruments
O 1 Inspect panel mounting for security and safety.
O 2 Check operation, mounting, and wiring of switches for
condition and safety.
O 3 Check automatic circuit breaker mounting and wiring for
condition and safety.
O 4 Inspect stall warner system for condition and security of
installation, perform operational check.
O O 5 Check wingtip position /strobe lights for security and
operation. If any one LED fails, the unit must be repaired or
replaced. Inspect the lense. Replace if there is excessive
scratching, discoloration or cracking.
O O 6 Inspect compass and compass deviation card for proper
indication and compensation.
O
1
7 Magnetic compass compensation.
O 8 Check pitot /static air pressure lines for condition and
leaks, perform operational check.
O
1
9 Check ASPEN EFD1000 PFD and 1000 MFD (reversion
mode) speed bands for compliance with instrument mark-
ings in the Pilot's Operating Handbook. Correct data if
necessary per ASPEN Installation Manual.
O
1
10 Check ASPEN EFD(s) in accordance with Aspen ICA (Doc.
# 900-00012-001 latest Revision).
O
1
O 11 Check MVP-50P per Electronics International Inc. ICA.
O
1
O 12 Check Garmin G5 for proper operation, secure attachment,
integrity of connectors and wiring, cleanliness, leakage of
hoses and tubes, and any evidence of damage.
O
2
13 If the optional Garmin G5 backup battery is installed,
perform Garmin G5 Battery Capacity Check as per Garmin
G5 Maintenance Manual (see Chapter 1).
Inspector:
Mechanic:
Date:
Serial No.:
Inspections
as specif
i
ed
eac
h
50 hours
eac
h
100 hours
1 Annual, every 12 calendar months
2 On the recommendation of the manufacturer, annual, every 12 calendar months