Foundry Switch and Router Installation and Configuration Guide
10 - 20 December 2000
If you have not set the time and date on the onboard system clock, the time stamp shows the amount of time
that has passed since the device was booted, in the following format:
<num>d<num>h<num>m<num>s
where:
<num>d day
<num>h hours
<num>m minutes
<num>s seconds
For example, 188d1h01m00s means the device had been running for 188 days, 11 hours, one minute, and
zero seconds when the Syslog entry with this time stamp was generated.
Example of Syslog Messages on a Device Whose Onboard Clock Is Set
The example shows the format of messages on a device whose onboard system clock has been set. Each time
stamp shows the month, the day, and the time of the system clock when the message was generated. For
example, the system time when the most recent message (the one at the top) was generated was October 15 at
5:38 PM and 3 seconds.
BigIron(config)# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 38 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dec 15 19:04:14:A:Fan 1, fan on right connector, failed
Dec 15 19:00:14:A:Fan 2, fan on left connector, failed
Dynamic Log Buffer (50 entries):
Oct 15 17:38:03:warning:list 101 denied tcp 209.157.22.191(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 2 packets
Oct 15 07:03:30:warning:list 101 denied tcp 209.157.22.26(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 2 packets
Oct 15 06:58:30:warning:list 101 denied tcp 209.157.22.198(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 packets
Example of Syslog Messages on a Device Whose Onboard Clock Is Not Set
The example shows the format of messages on a device whose onboard system clock is not set. Each time
stamp shows the amount of time the device had been running when the message was generated. For example,
the most recent message, at the top of the list of messages, was generated when the device had been running for
21 days, seven hours, two minutes, and 40 seconds.
BigIron(config)# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 38 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
21d07h02m40s:warning:list 101 denied tcp 209.157.22.191(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 2 packets

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foundry Networks Switch and Router and is the answer not in the manual?

Foundry Networks Switch and Router Specifications

General IconGeneral
BrandFoundry Networks
ModelSwitch and Router
CategorySwitch
LanguageEnglish

Related product manuals