EasyManua.ls Logo

Fronius RCU 5000i - Parameters of Pulse Characteristics; Ignition; Pulsing Parameters

Fronius RCU 5000i
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
113
EN
Parameters of pulse characteristics
Ignition
Ignition current
Strength of ignition current [A] set when welding begins. The ignition current depends on
the filler metal and wire diameter.
- In the case of low ignition current, the welding wire is not sufficiently preheated or
burned
- In the case of high ignition current, the filler wire is excessively preheated or burned
Pulsing parame-
ters
Overview of the pulsing parameters
Feeder creep speed
Wire feed speed [m/min] before welding begins (0 - currently set wire feed speed)
Ignition current time
The length of time [ms] the ignition current set when welding begins is active.
0 = no ignition current
40 = max. duration for ignition current
(1) Pulsing current time (6) Droplet detachment current
(2) Droplet-detachment time (7) Current rise when pulsing begins
(3) Current-rise (tau) (8) Ground current
(4) Current drop when pulsing ends (9) Pulse current
(5) Tau current drop
(8)
(7)
(3)
(9)
(1)
(4)
(5)
(5)
(2)
I (A)
t (s)
(6)

Table of Contents