Fronius RCU 5000i - Explanation of Q-Master Wire Feed Speed Values

Fronius RCU 5000i
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
97
EN
Explanation of Q-
Master wire feed
speed values
If the actual wire feed speed while job welding is greater than 15.5 m/min or less than 14.5
m/min for more than 0.3 sec, a reaction occurs in the form of a warning.
Wire feed speed command value
1)
E.g.: 15.0 m/min
- Value for the lower wirefeed speed limit - 0.5 m/min
= upper welding current limit value = 14.5 m/min
Wire feed speed command value
1)
E.g.: 15.0 m/min
+ Value for the upper wirefeed speed limit + 0.5 m/min
= upper wirefeed speed limit value = 15.5 m/min
Maximum duration of current deviation E.g.: 0.3 s
Reaction
2)
E.g.: Warning
1)
According to "Working parameters" screen
2)
According to "QMaster" screen