36
Setting working parameters
Setting working
parameters
MIG/MAG synergic welding: "Working parameters"
screen, arc length correction selected
Call up "MIG/MAG synergic welding"
menu item
Select "Working parameters" screen
by pressing the right arrow key (8):
– "Working parameters" screen ap-
pears.
Select the corresponding working pa-
rameters using down (6) or up (7) keys
Use the adjusting dial (18) to alter the
parameter value
– A parameter value can only be al-
tered within the defined setting
range. The setting range is high-
lighted.
The welding amperage, welding voltage and sheet thickness values appear in the display
area. If the "wirefeed speed" parameter is altered, the values in the display area also
change accordingly.
Trigger modes The following trigger modes can be set:
- 2-step
- Special 2-step
- 4-step
- Special 4-step
- Spot welding
Process The following processes can be set:
- Pulse (MIG/MAG pulse synergic welding)
- Standard (MIG/MAG standard synergic welding)
- CMT (Cold Metal Transfer)
1
2
3
4