EasyManua.ls Logo

Fronius RCU 5000i - Switching to Extra-Large Display; General

Fronius RCU 5000i
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
EN
Switching to extra-large display
General The wirefeed speed, welding current and welding voltage parameters can be displayed in
extra-large format. The wire feed unit and push-pull unit motor current is also shown in the
"Extra-large display" screen as an actual value.
Switching to ex-
tra-large display
MIG/MAG standard manual welding: "Extra-large dis-
play" screen
Call up "MIG/MAG standard manual
welding" menu item
Select "Extra-large display" screen by
pressing the right arrow key (8)
"Extra-large display" screen appe-
ars
The values for wire feed speed
and welding voltage can be alte-
red in the "Extra-large display"
screen using the adjusting dial
(18).
Welding current is a display value:
- during welding
... actual value
- following welding
... hold value
(1) Wire-feed unit motor current
(2) Push-pull unit motor current
(2)(1)
0.6 A
0.35 A
1
2

Table of Contents

Related product manuals