126
Parameters of CMT Advanced characteristics
General
Ignition In CMT processes, the ignition process is generally initiated with SFI (Spatter-Free Igni-
tion). The subsequent ignition behaviour in the CMT process is controlled by the following
parameters:
Hotstart
NOTE! The creation and editing of CMT/pulse characteristics (CMT+P) is a com-
plex task and therefore a core skill of Research & Development. Special meas-
urement technology (e.g. a high-speed camera, oscilloscope, etc.) as well as
extensive background knowledge is required for the creation and editing of
CMT+P characteristics.
The modification of CMT Advanced characteristics on-site simply optimizes the
application in question.
slaghammer On_1/Off_0
Function for removing slag at the end of the wire electrode
The wire electrode carries out a quick forward and reverse movement and touches the
surface of the workpiece until any slag drops off the wire electrode and ignition occurs.
The ignition parameter for aluminium is slaghammer = 0.
I_ignition
Command value for the ignition current [A], set when welding begins. The ignition current
depends on the filler metal and wire diameter.
t_ignition
Length of time [ms] that the parameters Vd_ignition and I_ignition are active when weld-
ing begins.
0 = no ignition current, no wire feed speed
99.98 = max. duration for ignition current and wirefeed speed command value
t_hotstart
The length of time [ms] that the change in arc power is active when welding begins.
0 = no change in the arc length
650 = max. duration for the change in arc power