133
EN
Pulsing parame-
ters
(7) tau_boostup
Non-linear current rise rate [ms] at the start of the boost phase (0.08 - 5.00)
(8) I_boost
Current command value [A] during the boost phase
(9) t_I_boost
Duration [ms] of the boost phase from the start of the boost current rise until the 
start of the boost current decrease
0 = no boost phase
99.98 = maximum duration of the boost phase 
(10) d_boostdown
Linear rate of current decrease [A/ms] following the boost phase
0 = no current decrease
1000 = maximum decrease in current 
(11) tau_boostdown
Non-linear current decrease rate [ms] following the boost phase (0.08 - 20)
(12) d_Ip1
Linear rate of rise in the pulsing current [A/ms]
0.1 = no pulsing current rise
2200 = maximum pulsing current rise 
(13) tau_Ip1
Non-linear pulsing current rise rate [ms]
(14) I_p1
Current command value [A] during the pulse phase
(15) t_p1
Duration of the pulsing current phase [ms] from the start of the current rise until the 
start of the current decrease
0 = no pulsing current phase
79.50 = maximum duration of the pulsing current phase