139
EN
Documentation
General The "Documentation" menu item serves to capture actual welding data during the welding
process.
The following welding data are documented:
- Welding current, welding voltage
- Exceeding or falling short of defined limit values (QMaster)
- Motor current of wire feeder and push-pull unit
- Component counter
- Errors arising during the welding process
- Events
For welding mode, the documentation of welding data is possible in the following menu
items:
- "MIG/MAG synergic welding"
- "MIG/MAG standard manual welding"
- "CC/CV mode" (if the "CC/CV mode" software option is installed on the power source)
- "Job welding"
Evaluating weld-
ing data
The documented welding data can be evaluated in two ways:
Direct evaluation of welding data Storing welding data on a memory card, subsequent
evaluation
(1)
RCU 5000i
(2)
(3)
(1)
RCU 5000i
(2)
(5)
(4)
(1) Power source (4) Card reader
(2) PC/laptop + RCU Data Receiver (5) Memory card
(3) LocalNet/RS 232 interface
Requirements: Requirements:
- PC or laptop with Microsoft® Excel - PC or laptop with Microsoft® Excel
- "RCU Data Receiver" software in-
stalled on PC/laptop
- "RCU Data Receiver" software in-
stalled on PC/laptop
- Data connection between PC/laptop
and the power source (e.g. via Local-
Net/RS 232 interface or "Ethernet"
option on the power source)
- Regular card reader for reading data
from the memory card