132
Overview: CMT
parameters, pulse
parameters
The CMT parameters are displayed in the screens "CMT - Param1" and "CMT - Param2".
The pulsing parameters are displayed on the "Pulsing parameter 1" and "Pulsing parame-
ter 2" screens.
Overview of the CMT+P Advanced characteristic parameters
CMT parameters
KSP Short-circuit phase (1) CMT cycle
BoP Boost phase (2) Pulse cycles
BrP Burn phase (3) Plasma phase
Negative cycle
KSP KSP(3)
(1) (2)
BoP
BrP
(18)(17)
(16)
(14)
(13)
(12)
(9)
(6)
(5)
(4)
I (A)
U (V)
t (s)
t (s)
t (s)
0
(15)
(19)
V
D
(m/s)
0
0
(7)
(8)
(10)
(11)
(4) vd_sc_wait
Wirefeed speed [m/min] following the boost phase until the dipping of the wire elec-
trode into the weld pool
(5) I_sc2
Current command value [A] with short circuit
(6) d_boostup
Linear current rise rate [A/ms] at the start of the boost phase
0 = no current rise
1000 = maximum rise in current