223
EN
Alphabetical overview of settable parameters
Explanation
"Minimum" and "maximum" are used for setting ranges that differ according to power
source, wire-feed unit, welding program, etc.
Parameters A - Z
Adjustable parameters
Explanation or function of the parameter
(Displayed on the power source)
Unit [Parameter unit, e.g.: m/min]
Range Setting range of the parameter, e.g. 0.5 - max.
Actual arc-length correction
for correcting the set arc length
Unit [%]
Range Depends on the "Arc-length corr. boundary" parameter in the "Correction
boundaries" screen, and the "Arc length correction" parameter in the "Work-
ing parameters" screen
Actual power correction
Time during which the droplet detachment current is active
(P)
Unit [m/min]
Range depends on the parameters "Power corr. limit: High" and "Power corr. limit:
Low" in the "Correction boundaries" screen
Anti-Stick
for switching the anti-stick function on and off (in MMA welding, pre-
vents a sticking electrode from burning out by switching off the cur-
rent)
(ASt)
Unit -
Range On/Off
Arc length correction
for correcting the arc length; as a SynchroPulse parameter it corrects
the arc length in the lower operating point (= mean wire feed speed
minus wire feed speed deviation)
(AL.1)
Unit [%]
Range -30 - +30
Arc-break watchdog
for presetting whether the arc-break watchdog is activated, or for pre-
setting the maximum duration of the arc break.
(Arc)
Unit [s]
Range Off/0.01 -2.00
Arc-length corr. boundary
for presetting the boundaries for correcting the arc length
(AL.c)
Unit [%]
Range ± 0 - 30
Arc-length correction 2
for correcting the arc length for SynchroPulse in the upper operating
point (= mean wire feed speed plus wire feed speed deviation)
(AL.2)
Unit [%]
Range -30 - +30