40
Switching to extra-large display
General The wirefeed speed, welding current and welding voltage parameters can be displayed in
extra-large format. The wire feed unit and push-pull unit motor current is also shown in the
"Extra-large display" screen as an actual value.
Switching to ex-
tra-large display
MIG/MAG synergic welding: "Extra-large display"
screen
Call up "MIG/MAG synergic welding"
menu item
Select "Extra-large display" screen by
pressing the right arrow key (8):
"Extra-large display" screen appe-
ars
The value for wire feed speed can
be altered in the "Extra-large dis-
play" screen using the adjusting
dial (18).
If the "Wirefeed speed" parameter is alte-
red, the values for welding current and wel-
ding voltage also change accordingly.
(1) Wire-feed unit motor current
(2) Push-pull unit motor current
(1) (2)
0.6 A
0.35 A
1
2

Table of Contents