EasyManua.ls Logo

Fronius RCU 5000i - Establishing Qmaster Values; Purpose of Qmaster Values; Explanation of Qmaster Values

Fronius RCU 5000i
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
144
Establishing QMaster values
Purpose of QMas-
ter values
Q-Master values can be established in the "Documentation" menu item. When storing jobs
these QMaster values are accepted as pre-sets. If during job welding set QMaster value
limits are exceeded over a specific period, one of the following reactions results:
- Power source switches off immediately
- A warning signal is given
- No reaction
Establishing
QMaster values
Establishing QMaster values
Call up the "Documentation" menu
item
Select "QMaster" screen by pressing
the right arrow key (8)
"QMaster" screen appears
Select the corresponding parameters
using down (6) or up (7) keys
Use the adjusting dial (18) to alter the
parameter value
A parameter value can only be al-
tered within the defined setting
range. The setting range is high-
lighted
Explanation of
QMaster values
Example:
Storing a job with a welding current of 250 A and a welding voltage of 35 V - the actual
QMaster values are accepted as a pre-set.
The following limit values result for the job:
If the actual welding current during job welding is greater than 275 A or less than 236 A for
more than 0.8 sec, the power source switches off.
1
2
3
4
IMPORTANT! If the "Max. duration of current-deviation" and "Max. duration of voltage-de-
viation" are entered as "Off" in the "QMaster" screen, the Q-Master function is deactivated.
Welding current according to job E.g.: 250.0 A
+ value in A for upper current limit + 25.0 A
= upper welding current limit value = 275.0 A
Welding current according to job E.g.: 250.0 A
- value in A for lower current limit - 14.0 A
= lower welding current limit value = 236.0 A
Maximum duration of current deviation E.g.: 0.8 s
Reaction E.g.: Shutdown

Table of Contents