143
EN
The RCU 5000i remote control unit supports 32MB - 1GB memory cards.
Example 1 Example 2 Example 3
Welding and weld-off
times
1 h 1 h 1 h
Duty cycle 100 % 100 % 100 %
Every n-th seam 1 1 1
Every n seconds 0.1 s 0.5 s Off
Actual welding data Yes Yes No
Default values Yes Yes Yes
Storage rate 650 kB/h 150 kB/h 5 kB/h
Change memory card after approx. 49 h after approx. 213 h after approx. 6400
h
Example 4 Example 5 Example 6
Welding and weld-off
times
1 h 1 h 1 h
Duty cycle 65 % / 35 % 65 % / 35 % 65 % / 35 %
Every n-th seam 1 1 1
Every n seconds 0.1 s 0.5 s Off
Actual welding data Yes Yes No
Default values Yes Yes Yes
Storage rate 400 kB/h 100 kB/h 5 kB/h
Change memory card after approx. 80 h after approx. 320 h after approx. 6400
h
IMPORTANT! At maximum documentation rates (Every n-th seam = 1, Every n seconds =
0.1, duty cycle 100%) change a full memory card within a maximum of 4 minutes, otherwise
the data buffered on the RCU 5000i remote control unit will be lost.