146
Setting maximum motor current
General In the "Documentation" menu item, the maximum motor current can be defined for the wire-
feed motor and the motor of a push-pull unit. When storing jobs, these maximum motor cur-
rent values are used as pre-sets. If the defined motor current values are exceeded for a
certain period during welding, then one of the following will occur:
- Power source switches off immediately
- A warning signal is given
- No reaction
Setting maximum
motor current
Documentation: "Motor current" screen
Call up the "Documentation" menu
item
Select "Motor current" screen by pres-
sing the right arrow key (8)
– "Motor current" screen appears
Select the corresponding parameters
using down (6) or up (7) keys
Use the adjusting dial (18) to alter the
parameter value
– A parameter value can only be al-
tered within the defined setting
range. The setting range is high-
lighted
1
2
3
4
IMPORTANT! If the "Maximum duration of current exceed" and "Maximum duration of cur-
rent exceed (PPU)" parameters are entered as "Off" in the "Motor current" screen, then the
motor current watchdog function is deactivated.