Setting maximum motor current
General In the "Documentation" menu item, the maximum motor current can be defined for the wire-
feed motor and the motor of a push-pull unit. When storing jobs, these maximum motor cur-
rent values are used as pre-sets. If the defined motor current values are exceeded for a
certain period during welding, then one of the following will occur:
- Power source switches off immediately
- A warning signal is given
- No reaction
Setting maximum
motor current
Documentation: "Motor current" screen
Call up the "Documentation" menu
item
Select "Motor current" screen by pres-
sing the right arrow key (8)
"Motor current" screen appears
Select the corresponding parameters
using down (6) or up (7) keys
Use the adjusting dial (18) to alter the
parameter value
A parameter value can only be al-
tered within the defined setting
range. The setting range is high-
lighted
1
2
3
4
IMPORTANT! If the "Maximum duration of current exceed" and "Maximum duration of cur-
rent exceed (PPU)" parameters are entered as "Off" in the "Motor current" screen, then the
motor current watchdog function is deactivated.