224
Boost correction
for setting the boost value in the case of CMT characteristic C0878
Unit -
Range -5.0 - +5.0
Burn-back correction
for setting burn-back time (= time between wire-feed unit stop and 
current stop at end of welding)
(bbc)
Unit [s]
Range -0.2 - +0.2
Burn-back pulse current
Strength of current pulse set at end of welding. The current pulse when at the end of weld-
ing produces a defined detachment of the last drop (a wire end with a small droplet is a 
precondition for good ignition). The parameter value must be greater than 0, otherwise 
there will be no current pulse.
Unit [A]
Range 0 - max.
Burn-back time
characteristic parameter for setting burn-back time (= time between 
wire-feed unit stop and current stop at end of welding)
(bbc)
Unit [s]
Range 0 - 0.4
Burn-off pulse time
The length of time the current pulse is active at end of welding.
Unit [ms]
Range 0 - 50
Burning voltage limit
for presetting the burning voltage limit during MMA welding
(Uco)
Unit [V]
Range Off/5 - max.
Characteristic
for setting the characteristic for electrode welding
(Eln)
Unit -
Range Constant current/0.1 - 20.0/constant power
Characteristic slope
Resistance value with which a drooping or neutral characteristic can be set.
Unit [Ohm]
Range 0 - 32767
CMT cycles
for setting the CMT cycles for a CMT/pulse characteristic
Unit -
Range 1 - 500
Comfort Stop sensitivity
for presetting the comfort stop sensitivity
(CSS)
Unit [V]
Range Off / 0.5 -5
Cooling unit
for presetting whether a cooling unit is to be switched on or off, or op-
erated automatically
(C-C)
Unit -
Range Off/On/Auto