(6) vd_sc_wait
(-6) EN_vd_sc_wait
Wirefeed speed [m/min] following the boost phase until the dipping of the wire elec-
trode into the weld pool
(7) I_sc2
(-7) EN_I_sc2
Current command value with short circuit [A]
(8) d_boostup
(-8) EN_d_boostup
Linear current rise rate [A/ms] at the start of the boost phase
0 = no current rise
1000 = maximum rise in current
(9) tau_boostup
(-9) EN_tau_boostup
Non-linear current rise rate [ms] at the start of the boost phase (0.08 - 5.00)
(10) I_boost
(-10) EN_I_boost
Current command value during the boost phase
(11) t_I_boost
(-11) EN_t_I_boost
Duration [ms] of the boost phase from the start of the boost current rise until the
start of the boost current decrease
0 = no boost phase
99.98 = maximum duration of the boost phase [ms]
(12) d_boostdown
(-12) EN_d_boostdown
Linear rate of current decrease [A/ms] following the boost phase
0 = no current decrease
1000 = maximum decrease in current
(13) tau_boostdown
(-13) EN_tau_boostdown
Non-linear current decrease rate [ms] following the boost phase (0.08 - 20)