5-29
11 Conrm that the tool is at the position shown in the left image
(grey square area), and press the [ENTER] key.
It will read the registration mark, and then plot the registration mark for
comparison. It will return to SENSOR OFFSET ADJ. screen once the
plotting is completed.
Feed direction of media
Distance adjustment value Y
Distance
adjustment
value X
Registration mark for adjustment
Registration mark
for comparison
Feed direction of media
Align the tool to this area
Supplement
Position of the registration mark is measured
at the center of the line.
12 Using the registration mark plotted in step 9, measure the
distance of how much the comparison registration mark
needs to be moved so both will overlap, and record the
value. As an example, in the gure above, it needs to move in
negative directions for both X and Y directions, so both of the
adjustment values will be negative values.
13 Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.
Supplement
Setting range is from -3.0mm to +3.0mm.
14 Press the POSITION ( ) key and increase or decrease the
setting value. Set the X value measured in step 12.
15 Conrm the setting and press the POSITION ( ) key
(PREVIOUS).
SENSOR OFFSET ADJ. is selected and it will return to SENSOR
OFFSET ADJ. screen.
16 Press the [4] key (Y).
SENSOR OFFSET ADJ. Y screen is displayed.