2-40
Setting the Speed
Set the speed of the tool that is used in each of the condition numbers.
Setting range : CE6000-40 1 to10 (in 1 cm/s increment), 10 to 60 (in 5 cm/s increment)
: CE6000-60 1 to10 (in 1 cm/s increment), 10 to 60 (in 5 cm/s increment), 64
: CE6000-120 1 to10 (in 1 cm/s increment), 10 to 70 (in 5 cm/s increment), 71
Supplement
On the CE6000-60, if you set speed as 64 and acceleration as 3, they will both appear as "*". In this case, both values will be
automatically calculated.
On the CE6000-120, if you set acceleration as 2, the speed cannot be set to 65 or more (65, 70, or 71). In this case, the speed and
acceleration will both appear as "*". Both values will be automatically calculated.
Operation
Supplement
Perform the settings in Normal mode.
1 Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
Supplement
It will return to CONDITION screen (1/3)
without changing the settings when you press
the [4] key (CANCEL) .
2 Press the [3] key (SPEED) .
SPEED setting screen is displayed.
* Display may vary depending on the selected tool condition number.
3 Press the POSITION (
) key and select the tool condition
number (CONDITION No.) .
Supplement
Guideline to set speed
See "Setting the Tool Condition"
P.2-32
.
4 Press the POSITION ( ) key and increase or decrease the
setting value.
5 Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION screen (1/3).
6 Press the [COND/TEST] key.
It will return to default screen.