2-36
Setting the Speed and Force (Simple mode)
In Simple mode, set the speed and force to be used with each tool condition.
Setting range (SPEED) : 5 to 60 (in 5cm/s increment)
Setting range (FORCE) : Standard Value + Adjusted Value
When the value (standard value + adjusted value) is as follows;
CE6000-40: 1 to 31
CE6000-60: 1 to 31
CE6000-120: 1 to 38
Operation
Supplement
Use Normal mode for changing the type of
blade, offset, and acceleration.
It will return to CONDITION screen (1/3)
without changing the settings when you
press the [4] key (CANCEL) .
1 Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/5) is displayed.
2 Press the POSITION ( ) key and select the setting.
Select the preset Media Type (Tool Conditions).
3 Press the [2] key (SPEED) to change the speed.
The screen below will appear.
Supplement
Press the [ENTER] key (SET), conrm the
settings, and then return to the READY
screen.
Press the [4] key (RETURN) to return to
the READY screen without changing any
settings.
4 Press the POSITION ( ) keys to change the current value.
You can enter any value between 5 and 60 (in increments of
5cm/s).
If you only want to change the speed, press the [ENTER] key
(SET). Setting will be set, and it will return to default screen.
Setting will be set, and it will return to default screen.