EasyManua.ls Logo

GRAPHTEC CE6000 SERIES - Setting the Step Pass

GRAPHTEC CE6000 SERIES
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-7
It may not cut the curved line smoothly if there is very short lines in the curve.
It will cut in the units of the specied value when the STEP PASS is used, which allows to control the short lines
with certain length, resulting to stable rotation of the blade for higher cut quality.
Setting range of STEP PASS is from 0 to 20.
Actual length of the STEP PASS is the value of the STEP PASS multiplied by the distance set in the "STEP SIZE".
P.11-5
"Setting the Step Size (STEP SIZE)"
Supplement
This setting will be saved even if the power is shut off.
The cut image may not be what you intended if the set value is too large. It is recommended to set to "1" for normal use.
Operation
Supplement
Perform the settings in Normal mode.
1 Press the [PAUSE/MENU] key.
MENU screen is displayed.
2 Press the [1] key (TOOL).
TOOLS SETTING screen (1/3) is displayed.
3 Press the [2] key (STEP PASS).
STEP PASS setting screen is displayed.
Supplement
Setting range is from 0 to 20.
4 Press the POSITION ( ) key and increase or decrease the
setting value.
Supplement
It will return to TOOLS setting screen (1/3)
without changing the settings when you press
the POSITION ( ) key (CANCEL).
5 Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to TOOLS setting screen (1/3).
6 Press the [PAUSE/MENU] key.
It will return to default screen.
7.2
Setting the Step Pass

Table of Contents