1-15-96 96-8100
193
TABLE OF CONTENTS
PARAMETERS
SERVICE
MANUAL
VF-SERIES
Parameter 210 X TOOL CHANGE OFFSET
For X-axis; displacement from home switch to tool change position and ma
chine zero. About 4.6 inches so for a 2000 line encoder this gives:
4.6 x 33867 = 155788
Parameter 211 Y TOOL CHANGE OFFSET
For Y-axis; displacement from home switch to tool change position and ma
chine zero. About 4.6 inches so for a 2000 line encoder this gives:
4.6 x 33867 = 155788
Parameter 212 A TOOL CHANGE OFFSET
For A-axis; displacement from home switch to tool change position and ma
chine zero. About 4.6 inches so for a 2000 line encoder this gives:
4.6 x 33867 = 155788
Parameter 213 B TOOL CHANGE OFFSET
For B-axis; displacement from home switch to tool change position and ma
chine zero. About 4.6 inches so for a 2000 line encoder this gives:
4.6 x 33867 = 155788
Parameter 214 RESERVED
Parameter 215 CAROUSEL OFFSET
Parameter used to align tool 1 of tool changing carousel precisely. Units are
encoder steps.
Parameter 216 CNVYR RELAY DELAY
Delay time in 1/50 seconds required on conveyor relays before another action
can be commanded. Default is 5.
Parameter 217 CNVYR IGNORE OC TIM
Amount of time in 1/50 seconds before overcurrent is checked after conveyor
motor is turned on. Default is 50.
Parameter 218 CONVYR RETRY REV TIM
Amount of time that the conveyor is reversed in 1/50 seconds after overcurrent
is sensed. Default is 200.
Parameter 219 CONVYR RETRY LIMIT
Number of times that the conveyor will cycle through the reverse/forward
sequencing when an overcurrent is sensed before the conveyor will shut down.
An overcurrent is sensed when chips jam the conveyor. By reversing and then
forwarding the conveyor, the chip jam may be broken. Default is 3.
Parameter 220 CONVYR RETRY TIMEOUT
Amount of time in 1/50 seconds between consectutive overcurrents in which
the overcurrents is considered another retry. If this amount of time passes
between overcurrents then the retry count is set to (0). Default is 1500, 30
minutes.

Table of Contents

Other manuals for Haas VF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haas VF Series and is the answer not in the manual?

Haas VF Series Specifications

General IconGeneral
Machine TypeVertical Machining Center
ControlHaas CNC Control
Z-Axis Travel20-30 inches (varies by model)
Y-Axis Travel16 - 30 inches (varies by model)
Spindle Motor20-30 hp (depending on model)
Tool Capacity20-40 tools (varies by model)