ALARMS
HAAS AUTOMATION, INC.
SERVICE
MANUAL
VF-SERIES
192 B Axis Z Ch Missing Same as 153.
193 B Axis Drive Fault Same as 161.
194 B Zero Ret Margin Same as 168.
Too Small
195 B Cable Fault Same as 182.
196 Coolant Spigot Failure Spigot failed to achieve commanded location after two (2) attempts.
197 100 Hours Unpaid Bill Call your dealer.
198 Precharge Failure During TSC operation, the precharge failed for greater than 0.1 seconds. It will shut off the
feed, spindle and pump all at once. If received, check all air lines and the air supply pressure.
201 Parameter CRC Error Parameters lost maybe by low battery. Check for a low battery and low battery alarm.
202 Setting CRC Error Settings lost maybe by low battery. Check for a low battery and low battery alarm.
203 Lead Screw CRC Error Lead screw compensation tables lost maybe by low battery. Check for CRC Error low battery
and low battery alarm.
204 Offset CRC Error Offsets lost maybe by low battery. Check for a low battery and low battery alarm.
205 Programs CRC Error Users program lost maybe by low battery. Check for a low battery and low battery alarm.
206 Internal Program Error Software Error; Call your dealer.
207 Queue Advance Error Software Error; Call your dealer.
208 Queue Allocation Error Software Error; Call your dealer.
209 Queue Cutter Software Error; Call your dealer.
Comp Error
210 Insufficient Memory Not enough memory to store users program. Check the space available in the LIST PROG
mode and possibly delete some programs.
211 Odd Prog Block Software Error; Call your dealer.
212 Program Integrity Error Software Error; Call your dealer.
213 EPROM CRC Error Electronics fault; Call your dealer.
214 No. of Programs Indicates that the number of programs disagrees with the internal
Changed variable that keeps count of the loaded programs. Call your dealer.
215 Free Memory PTR Indicates the amount of memory used by the programs counted in the
Changed system disagrees with the variable that points to free memory. Call your dealer.

Table of Contents

Other manuals for Haas VF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haas VF Series and is the answer not in the manual?

Haas VF Series Specifications

General IconGeneral
Machine TypeVertical Machining Center
ControlHaas CNC Control
Z-Axis Travel20-30 inches (varies by model)
Y-Axis Travel16 - 30 inches (varies by model)
Spindle Motor20-30 hp (depending on model)
Tool Capacity20-40 tools (varies by model)

Related product manuals