216 EPROM Speed Failure Indicates that an EPROM internal driver has weakened so that data read from that EPROM may
be unreliable. Call your dealer.
217 X Axis Phasing Error Error occured in phasing initialization of brushless motor. This can be caused by a bad
encoder, or a cabling error.
218 Y Axis Phasing Error Same as above.
219 Z Axis Phasing Error Same as above.
220 A Axis Phasing Error Same as above.
221 B Axis Phasing Error Same as above.
222 C Axis Phasing Error Same as above.
223 X Transition Fault Illegal transition of count pulses in X axis. This alarm usually indicates that the encoder has
been damaged and encoder position data is unreliable. This can also be caused by loose
connectors at the MOCON PCB.
224 Y Transition Fault Same as above.
225 Z Transition Fault Same as above.
226 A Transition Fault Same as above.
227 B Transition Fault Same as above.
228 C Transition Fault Same as above.
231 Jog Handle Transition Same as 223.
Fault
232 Spindle Transition Fault Same as above.
233 Jog Handle Cable Fault Cable from jog handle encoder does not have valid differential signals.
234 Spindle Enc. Cable Fault Cable from spindle encoder does not have valid differential signals.
235 Spindle Z Fault Same as 139.
240 Empty Prog or No EOB Software Error; Call your dealer.
241 Invalid Code RS-232 load bad. Data was stored as comment. Check the program being received.
242 No End Check input file for a number that has too many digits
243 Bad Number Data entered is not a number.
244 Missing ) Comment must end with a ) .
245 Unknown Code Check input line or data from RS-232. This alarm can occur while editing data into a program
or loading from RS-232.
246 String Too Long Input line is too long. The data entry line must be shortened.
247 Cursor Data Base Error Software Error; Call your dealer.