13. Check that the green STATUS LED on the BKMF is blinking.
14. In the Maintenance Utility window, click Hardware > Controller
Chassis.
15. Click the BKMF tab.
16. Confirm that the status of the replacement battery is Normal.
17. Log out and close the Maintenance Utility window.
Checking battery cable connections
Procedure
1. In the Alert Detail window of the maintenance utility, click Close.
2. In the maintenance utility, clickController Chassis in the left pane, and
then click the BKMF tab.
124 Replacing a battery
Service Guide for VSP Gx00 and VSP Fx00 Models