Loading...
Checking a fan
Before you begin
Confirm that the storage system power is turned on.
Procedure
1. Start the maintenance utility.
2. In the Maintenance Utility window, click Hardware > Controller
Chassis.
3. In the Controller Chassis window, click the CTLs tab.
4. To display the most recent status of the fan, click Refresh.
5. Confirm that the status of the fan to be replaced is Warning.
6. Use the amber CTL WARN LED to identify the failed fan that needs to be
replaced:
If the LED blinks 1 time, replace fan 0.
If the LED blinks 2 times, replace fan 1.
7.
130 Replacing a fan
Service Guide for VSP Gx00 and VSP Fx00 Models