5. Wait at least 30 seconds, and then insert the new power supply, just
before the "shield finger."
6. Push the power supply into the unit gently until the power supply latch
clicks.
7. Connect the power cable to the power supply, and then secure the cable
by the cable holder
8. Confirm that the red ALM/RDY LED is off at the power supply and the
green ALM/RDY LED is on.
If the red ALM/RDY LED does not go off after more than 30 minutes
following replacement of the power supply, remove the power supply,
wait at least 30 seconds, and then reinstall it.
Checking the power supply connections on a host port expansion
chassis
Using the following procedure, you can check the power supply connection on
a host port expansion chassis.
Procedure
1. In the Alert Detail window of the maintenance utility, click Close.
2. In the left pane, under Hardware, click Channel Board Box to check
the location of the power supply unit on the host port expansion chassis
fan (CHBBFAN).