Note: Check the target power supply units and power cables only.
Do not touch other power supply units and power cables.
3. Check the connection of the target power supply units and power cables:
For the CBSS/CBSL, push the power supply units all the way into their
slots and check that the latches are locked.
For the CBLM/CBLH, push the power supply units all the way into their
slots and tighten using the blue screws. If the power cables connected
to the target power supply units are loose, push the plugs of the
power cables into the sockets of the power supply units to connect the
cables securely.
4. Log out of maintenance utility to close the window.
Confirming the power supply unit status
Procedure
1. Click Hardware > Controller Chassis or Hardware > Drive Box.
2. In the Controller Chassis or Drive Box window, click the PSs tab.