EasyManua.ls Logo

Hitachi G200 - Checking a Drive

Hitachi G200
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checking a drive
Procedure
1. Start the maintenance utility.
2. Click Hardware > Controller Chassis Hardware > Drive Box.
3. Click the Drives tab.
4. Confirm that the status of the drive to be replaced is Warning, Failed,
Blocked, Copy incomplete, or Reserved.
5. Click Refresh.
6. Remove the front bezel and check whether the red ALM LED on the failed
drive is on or off:
If the LED is on, replace the drive.
If the LED is off, proceed to Blocking the drive on page 109.
Note: If the ALM LED is ON but the drive status is neither Blocked
nor Failed, go to the HDS Support Portal at https://
support.hds.com/en_us/contact-us.html.
108 Replacing a drive
Service Guide for VSP Gx00 and VSP Fx00 Models

Table of Contents

Other manuals for Hitachi G200

Related product manuals