CBSL front panel without bezel
The following table describes the definitions of the CBSL controller front panel
LEDs.
Number
Item Description
1
ACT LED Green: Normal operation.
Blink green: Drive is being
accessed.
2
ALM LED
Red: Drive stopped due to a
failure and can be replaced.
3
POWER, READY, WARNING, and
ALARM LEDs
Note: When System Option
Mode 1097 is set to ON, the
WARNING LED does not blink,
even if the following failure
service information messages
(SIM) are issued: 452xxx,
462xxx, 3077xx, 4100xx, and
410100.
4
POWER ON/OFF (main switch) Powers the storage system.
5
Large form factor drives The twelve 3.5-inch large form
factor drives are positioned
horizontally. The slots are
organized in the following
order:
8 9 10 11
4 5 6 7
0 1 2 3
CBSL rear panel
The following table describes the definitions of the CBSL controller rear panel
LEDs.