Blocking a BKMF
Before you begin
Confirm that a backup module is installed in the backup module enclosure.
Confirm that the storage system power is turned on.
Confirm that the red STATUS LED on the backup module to be replaced is
on.
Use the Dump tool to collect the storage system configuration information.
Procedure
1. Start the maintenance utility.
2. Click Hardware > Controller Chassis.
3. Click the BKMFs tab.
4. To display the most recent status of the BKMF, click Refresh.
5. Confirm that the status of the backup module to be replaced is Warning.
If Warning appears for BKMF Status and ? appears for the Battery
Lifespan Remaining values of the batteries, resolve the Warning for
BKMF Status so the ? returns to a numeral value.
272 Replacing a backup module