Replaceable parts
The following list shows the components that you can replace on site for the
storage systems.
Note: For the dense intermix drive tray, the only user-replacement procedure
supported by Hitachi is installing or replacing disk drives.
Drive (replacing drives on the flash module drive tray is is strictly limited
to Hitachi and certified partners)
Battery
Fan for CBSS or CBSL
Power supply unit
Controller
Cache memory
Front end module
Small Form-Factor Pluggable
Back end module for CBLM or CBLH
ENC
SAS cable
Cache Flash Memory
LAN blade
Backup module (BKM) for CBSS or CBSL
Backup module (BKMF) for CBLM or CBLH
Identifying hardware faults
There are several ways the storage system can alert you to failures:
When notified about an error by email or the Simple Management Network
Protocol (SMNP).
When a failure is indicated by storage system LED (for example, WARNING
or ALARM LED goes on or READY LED does not go on).
To identify a failed part and recover the storage system:
Procedure
1. Check the serial number of the storage system referenced in the email
notification or SNMP alert.
2. Start the maintenance utility.
3. In the Maintenance Utility window, check the serial number of the
storage system where the error was reported. Confirm that this serial
number matches the one in step 1.
24 Verifying component failures
Service Guide for VSP Gx00 and VSP Fx00 Models