EasyManua.ls Logo

Hiwin D1-N Series - Page 86

Hiwin D1-N Series
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
86 / 183
Assembly and Commissioning Instructions Servo amplifier D1-N
15.10.2015
“Position mode”:
The drive amplifier receives the nominal position value via I/O interface X6. Differ-
ent signal types, e.g. “Pulse and Direction”, “Pulse Up /Pulse Down” and “Quadra-
ture (A B I)” can be selected here. “Electronic gear” signal scaling can also be un-
dertaken. This reflects the ratio of motor increments (output counts) to input puls-
es (at controller end). The position specification can be connected via “High Speed
Pulse Input” or “Low Speed Pulse Input”. For the precise input specifications, refer
to section 5.7.1.
Figure 8.30: “Configuration Center” – position mode without CoE

Table of Contents

Other manuals for Hiwin D1-N Series