EasyManua.ls Logo

HP Integrity rx2620 - Specifying SCSI Parameters

HP Integrity rx2620
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix C
Utilities
Specifying SCSI Parameters
187
Last Clear time: 10/21/01 5:00p
Number of total entries in PDT: 50
Number of used entries in PDT: 0
Number of free entries in PDT: 50
Number of single-bit entries in PDT: 0
Number of multi-bit entries in PDT: 0
Address of first multi-bit error: 0x0000000000000000
sysmode
Display or modify the system mode.
Syntax
sysmode <normal | admin| service>
Parameters
<normal> sets system mode to normal
<admin> sets system mode to admin
<service> sets system mode to service
Operation
If specified alone, sysmode displays the system mode. If a mode is specified as a parameter, then the system
mode is changed. This new mode takes effect immediately. The system mode is retained on successive boots.
Interaction with sysmode in a variety of scenarios is outlined below.
Example C-20 sysmode Command
Shell> sysmode
System Mode: NORMAL
Shell> sysmode admin
You are now in admin mode.
Shell> sysmode service
You are now in service mode.
Shell> sysmode normal
You are now in normal mode
Specifying SCSI Parameters
The following SCSI parameters may be configured for the SCSI board:
SCSI ID (SCSI initiator ID)
Maximum data transfer rate (SCSI rate)
•Bus width
Whether the HBA is bootable (driver support)
Avoid bus resets (secondary cluster server)

Table of Contents