Shell> sysmode service
Current System Mode: ADMIN
You are now in SERVICE mode.
Step 16. Use the sysset command to enter the product data:
Shell> sysset prodname "server rx2620"
Step 17. Use the sysset command to verify all values are set:
Shell> sysset
System Information:
Manufacturer: hp
Product Name: server rx2620
Product Number: AB332A
Secondary Product Number is Identical
Serial number: US51884101
Secondary Serial Number is Identical
UUID: A8F2D6EC-DBE5-11D9-9172-AE65D056B60F (Valid)
Secondary UUID is Identical
Product ID: 0x10A
Step 18. Use the EFI date and time commands to set the correct local date and time.
Step 19. Review the system configuration in the
Boot Configuration Menu and/or EFI shell and reconfigure
settings as necessary.
Step 20. Boot the server and resume normal operation.
Removing and Replacing the Power Supply Interface Module
The power supply interface (PSI) module supports up to two redundant power supplies.
Removing the Power Supply Interface Module
Step 1. Turn off the server, disconnect all power and external cables, and remove the top metal cover.
Step 2. Remove the system board. See “Removing and Replacing the System Board” on page 92.
Step 3. Remove the power supply (or supplies). See “Removing the Power Supply” on page 56.
Step 4. Lift the power cables out of their metal holding clips. See Figure 4-58 for more information.

Table of Contents

Other manuals for HP Integrity rx2620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2620 and is the answer not in the manual?

HP Integrity rx2620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx2620
CategoryServer
LanguageEnglish

Related product manuals