191
Ctrl[41] 16550 Serial UART Driver
Ctrl[42] VT-100+ Serial Console
Ctrl[54] VenHw(D65A6B8C-71E5-4DF0-A909-F0D2992B5AA9)
In the preceding example, the SCSI interface information is shown highlighted bold. You can tell
the information is for the SCSI interface because the path on the first line—Acpi(HWP0002,100)—
is the path from the information displayed by the info io command. The next two lines are for the
SCSI interface two channels, one line for each channel (they contain the SCSI interface description
[LSI Logic Ultra320 SCSI Controller]). Note the value shown for Ctrl—17 and 18—at the
beginning of each of those lines; this is the controller’s handle for each channel. You need to know
it for the next step.
NOTE The controller’s handle values change on every boot.
Step 3. Still at the EFI shell prompt, type this command to obtain the EFI driver’s handle for the SCSI
interface:
drvcfg
A list of all EFI-capable configurable components in the server is displayed. The output may look
like this:
Shell> drvcfg
Configurable Components
Drv[3D] Ctrl[15] Lang[eng]
Drv[3F] Ctrl[19] Lang[eng]
Drv[45] Ctrl[17] Lang[eng]
Drv[45] Ctrl[18] Lang[eng]
This listing shows which driver controls which device (controller). In the above example, the SCSI
interface information is shown highlighted bold. You can tell the information is for this SCSI
interface because the values shown for Ctrl—17 and 18—are the controller’s handles for the SCSI
interface two channels (from the information displayed by the devtree command).
NOTE The EFI driver’s handle values change on every boot.
TIP From this command (drvcfg), we recommend you record these two pieces of
information for each channel of each SCSI interface for parameters to be changed:
• Drv (the EFI driver’s handle)
• Ctrl (the controller’s handle)
Step 4. Using the information (the driver’s handle [Drv] and the controller’s handle [Ctrl]) from the
drvcfg command, start the EFI SCSI Setup Utility for one channel of this SCSI interface. Still at
the EFI shell prompt, type this command:
drvcfg -s drvr_handle cntrl_handle
where
• drvr_handle is the handle of the driver that controls the channel whose SCSI ID you want to
display or change

Table of Contents

Other manuals for HP Integrity rx2620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2620 and is the answer not in the manual?

HP Integrity rx2620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx2620
CategoryServer
LanguageEnglish

Related product manuals