Testing power supply
Before replacing the power supply, use the Built-In Self-Test (BIST) feature to learn if the power supply
still works.
To test the power supply:
1. Unplug the AC power.
2. Disconnect all internal power supply cables from the system board.
3. Plug in AC power.
If the green BIST LED (illustrated below) on the rear of the workstation is illuminated and the
fan is spinning, the power supply is functional.
If the green BIST LED is not illuminated or the fan is not spinning, replace the power supply.
Figure 5-1 Testing power supply with BIST LED
Table 5-3 Power supply problems
Problem Cause Solution
Power supply shuts down
intermittently.
Power supply fault. Replace the power supply.