Problem Cause Solution
Diskette is write-protected. Use another diskette or remove the write protection.
Writing to the wrong drive. Verify the drive letter in the path statement.
Not enough space is left on the
diskette.
Use another diskette.
Diskette write-control is
enabled.
Use the Computer Setup (F10) Utility to verify the storage
security feature disabled settings.
Diskette is damaged. Replace the damaged disk.
Cannot format diskette. Invalid media reported. When formatting a disk in MS-DOS, you might need to
specify diskette capacity. For example, to format a 1.44–
MB diskette, enter the following command at the MS-
DOS prompt: FORMAT A: /F:1440
A problem has occurred with a disk
transaction.
The directory structure is bad,
or there is a problem with a file.
Right-click Start, select Explore, and then select a drive.
Select File>Properties>Tools. Under Error-checking,
select Check Now.
Diskette drive cannot read
a diskette.
Diskette is not formatted. Format the diskette.
You are using the wrong
diskette type for the drive type.
Verify the type of drive that you are using and use the
correct diskette type.
You are reading the wrong
drive.
Verify the drive letter in the path statement.
Diskette is damaged. Replace the diskette with a new one.
“Invalid system disk” message is
displayed.
A diskette that does not contain
the system files needed to start
the workstation has been
inserted into the drive.
When drive activity stops, remove the diskette and press
the Spacebar. The workstation should start up.
Diskette error has occurred. Restart the workstation by pressing the power button.
Cannot Boot to Diskette. Diskette is not bootable. Replace with a bootable diskette.
Diskette boot has been
disabled in Computer Setup.
Run Computer Setup and enable diskette boot in
Storage>Boot Order.
Removable media boot has
been disabled in Computer
Setup.
Run Computer Setup and enable Removable Media Boot
in Storage>Storage Options.
Diskette MBR validation is
enabled.
Run the Computer Setup (F10) Utility and disable
Diskette MBR Validation in Storage>Storage Options.
Solving hard drive problems
Table 5-5 Hard drive problems
Problem Cause Solution
Hard drive error occurs. Hard disk has bad sectors or
has failed.
Use a utility to locate and block usage of bad sectors. If
necessary, reformat the hard disk.
Or, if the drive is detected by the BIOS, then run DPS Self-
test .
Table 5-4 Diskette problems (continued)
ENWW Customer Self Help 117

Table of Contents

Other manuals for HP xw4600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP xw4600 and is the answer not in the manual?

HP xw4600 Specifications

General IconGeneral
Tcase72.4 °C
Bus typeFSB
SteppingE0
Processor cache6 MB
Processor cores2
Processor modelE8400
System bus rate- GT/s
Processor familyIntel® Core™2 Duo
Processor seriesIntel Core 2 Duo E8000 Series
Processor socketLGA 775 (Socket T)
Processor codenameWolfdale
Processing Die size107 mm²
Processor frequency3 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)65 W
Number of processors installed1
CPU multiplier (bus/core ratio)9
Number of Processing Die Transistors410 M
Audio systemHigh Definition Audio
Product typeWorkstation
Motherboard chipsetIntel® X38 Express
ECCYes
Internal memory2 GB
Memory clock speed800 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory8 GB
Memory layout (slots x size)2 x 1 GB
HDD speed7200 RPM
HDD capacity250 GB
HDD interfaceSATA
Optical drive typeDVD-RW
Graphics card-
Networking featuresGigabit Ethernet (10/100/1000)
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Power supply475 W
Chassis typeTower
Country of originChina
Processor codeSLB9J
Processor ARK ID33910
Processor package size37.5 x 37.5 mm
On-board graphics card modelNot available
Weight and Dimensions IconWeight and Dimensions
Depth456 mm
Width168 mm
Height450 mm
Weight19000 g

Related product manuals